Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Neurosurg ; 128(6): 1653-1660, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-28784032

RESUMO

OBJECTIVE There is no established method of noninvasive intracranial pressure (NI-ICP) monitoring that can serve as an alternative to the gold standards of invasive monitoring with external ventricular drainage or intraparenchymal monitoring. In this study a new method of NI-ICP monitoring performed using algorithms to determine ICP based on acoustic properties of the brain was applied in patients undergoing invasive ICP (I-ICP) monitoring, and the results were analyzed. METHODS In patients with traumatic brain injury and subarachnoid hemorrhage who were undergoing treatment in a neurocritical intensive care unit, the authors recorded ICP using the gold standard method of invasive external ventricular drainage or intraparenchymal monitoring. In addition, the authors simultaneously measured the ICP noninvasively with a device (the HS-1000) that uses advanced signal analysis algorithms for acoustic signals propagating through the cranium. To assess the accuracy of the NI-ICP method, data obtained using both I-ICP and NI-ICP monitoring methods were analyzed with MATLAB to determine the statistical significance of the differences between the ICP measurements obtained using NI-ICP and I-ICP monitoring. RESULTS Data were collected in 14 patients, yielding 2543 data points of continuous parallel ICP values in recordings obtained from I-ICP and NI-ICP. Each of the 2 methods yielded the same number of data points. For measurements at the ≥ 17-mm Hg cutoff, which was arbitrarily chosen for this preliminary analysis, the sensitivity and specificity for the NI-ICP monitoring were found to be 0.7541 and 0.8887, respectively. Linear regression analysis indicated that there was a strong positive relationship between the measurements. Differential pressure between NI-ICP and I-ICP was within ± 3 mm Hg in 63% of data-paired readings and within ± 5 mm Hg in 85% of data-paired readings. The receiver operating characteristic-area under the curve analysis revealed that the area under the curve was 0.895, corresponding to the overall performance of NI-ICP monitoring in comparison with I-ICP monitoring. CONCLUSIONS This study provides the first clinical data on the accuracy of the HS-1000 NI-ICP monitor, which uses advanced signal analysis algorithms to evaluate properties of acoustic signals traveling through the brain in patients undergoing I-ICP monitoring. The findings of this study highlight the capability of this NI-ICP device to accurately measure ICP noninvasively. Further studies should focus on clinical validation for elevated ICP values.


Assuntos
Algoritmos , Pressão Intracraniana , Monitorização Fisiológica/métodos , Adulto , Idoso , Lesões Encefálicas Traumáticas/fisiopatologia , Ventrículos Cerebrais , Cuidados Críticos , Drenagem , Feminino , Humanos , Hipertensão Intracraniana/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Sensibilidade e Especificidade , Hemorragia Subaracnóidea/fisiopatologia
2.
World Neurosurg ; 106: 557-562, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28712896

RESUMO

BACKGROUND: Currently, intracranial pressure (ICP) is measured by invasive methods with a significant risk of infectious and hemorrhagic complications. Because of these high risks, there is a need for a noninvasive ICP (nICP) monitor with an accuracy similar to that of an invasive ICP (iICP) monitor. OBJECTIVE: We sought to assess prospectively the accuracy and precision of an nICP monitor compared with iICP measurement in severe traumatic brain injury (TBI) patients. METHODS: Participants were ICP-monitored patients who had sustained TBI. In parallel with the standard invasive ICP measurements, nICP was measured by the HeadSense HS-1000, which is based on sound propagation. The device generated an acoustic signal using a small transmitter, placed in the patient's ear, and picked up by an acoustic sensor placed in the other ear. The signal is then analyzed using proprietary algorithms, and the ICP value is calculated in millimeter of mercury (mm Hg). RESULTS: Analysis of 2911 paired iICP and nICP measurements from 14 severe TBI patients showed a good accuracy of the nICP monitor indicated by a mean difference of 0.5 mm Hg. The precision was also good with a standard deviation of 3.9 mm Hg. The Pearson r correlation was 0.604 (P < 0.001). CONCLUSIONS: The HeadSense HS-1000 nICP monitor seems sufficiently accurate to measure the ICP in severe TBI patients, is patient friendly, and has minimal risk of complications.


Assuntos
Lesões Encefálicas Traumáticas/fisiopatologia , Pressão Intracraniana/fisiologia , Adulto , Idoso , Lesões Encefálicas Traumáticas/complicações , Hemorragia Cerebral Traumática/etiologia , Hemorragia Cerebral Traumática/fisiopatologia , Desenho de Equipamento , Feminino , Humanos , Hipertensão Intracraniana/diagnóstico , Hipertensão Intracraniana/etiologia , Hipertensão Intracraniana/fisiopatologia , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/instrumentação , Estudos Prospectivos , Hemorragia Subaracnoídea Traumática/etiologia , Hemorragia Subaracnoídea Traumática/fisiopatologia , Adulto Jovem